Home / Treatment / Simultaneous integrated boost in early breast cancer cuts visits without losing local control

Simultaneous integrated boost in early breast cancer cuts visits without losing local control

The phase 3 IMPORT HIGH trial concludes that delivering the tumour-bed boost simultaneously with whole-breast radiotherapy is safe, maintains excellent local control and reduces the number of patient visits, with no added advantage from dose escalation.

What was known

A tumour-bed boost after whole-breast radiotherapy improves local control in early breast cancer, but it requires extra visits and can increase breast hardness. A strategy was needed that shortened treatment while maintaining local control and without increasing toxicity.

What this work adds

IMPORT HIGH is a phase 3, open-label, randomised, non-inferiority trial that recruited women after breast-conserving surgery for pT1-3pN0-3aM0 invasive carcinoma at radiotherapy and referral centres in the UK. Patients were allocated 1:1:1 to three schedules: the control group received 40 Gy in 15 fractions to the whole breast plus a sequential photon tumour-bed boost of 16 Gy in 8 fractions; test group 1 received 36 Gy in 15 fractions to the whole breast, 40 Gy in 15 fractions to the partial breast and a concomitant photon boost of 48 Gy in 15 fractions to the tumour bed; test group 2 received the same schedule with a concomitant boost of 53 Gy in 15 fractions. The boost clinical target volume was clip-defined. The primary endpoint was ipsilateral breast tumour relapse, analysed by intention to treat. A total of 2617 patients were recruited between March 2009 and September 2015: 871 in the control group, 874 in test group 1 and 872 in test group 2. Median boost clinical target volume was 13 cm³ (IQR 7-22). Median follow-up was 74 months.

Main results

There were 76 ipsilateral breast tumour relapses: 20 in the control group, 21 in test group 1 and 35 in test group 2. Five-year relapse incidence was 1.9% (95% CI 1.2-3.1) in the control group, 2.0% (1.2-3.2) in test group 1 and 3.2% (2.2-4.7) in test group 2. Estimated absolute differences versus the control group were 0.1% (-0.8 to 1.7) for test group 1 and 1.4% (0.03-3.8) for test group 2. The upper confidence limit for test group 1 versus the control group indicated non-inferiority for 48 Gy. Cumulative five-year incidence of clinician-reported moderate or marked breast induration was 11.5% in the control group, 10.6% in test group 1 (p=0.40 vs control) and 15.5% in test group 2 (p=0.015 vs control).

What it means

In all groups, five-year relapse incidence was lower than the 5% originally expected, regardless of boost sequencing. Dose escalation is not advantageous. With small boost volumes, five-year rates of moderate or marked adverse events were low. Simultaneous integrated boost in IMPORT HIGH was safe and reduced patient visits.

Reading from the breast unit

Fewer visits have clear organisational implications: less travel for the patient and better use of radiotherapy machines. Adopting simultaneous boost requires careful dosimetric planning and quality control of the clip-defined target volume.

Reference: IMPORT HIGH trial investigators. Dose-escalated simultaneous integrated boost radiotherapy in early breast cancer (IMPORT HIGH): a multicentre, phase 3, non-inferiority, open-label, randomised controlled trial. Lancet, 2023. DOI

Leave a Reply

Your email address will not be published. Required fields are marked *