Home / Prevention & Screening / Digital tomosynthesis: new benchmark values for breast screening

Digital tomosynthesis: new benchmark values for breast screening

Digital breast tomosynthesis (DBT) achieves better screening performance than digital mammography on most metrics in US community practice, according to new benchmark values published by the Breast Cancer Surveillance Consortium (BCSC).

What was known

Digital mammography (DM) has long been the reference technique in screening programmes, while digital tomosynthesis, which produces three-dimensional images of the breast, has been adopted progressively. Updated benchmark values reflecting real-world practice, rather than only expert centres, were needed to compare the performance of individual services and radiologists.

What this work adds

This retrospective study collected DBT screening examinations from five BCSC registries between 2011 and 2018. A total of 896,101 women and 2,301,766 screening examinations were included: 458,175 with DBT (median age 58 years) and 1,843,591 with DM (median age 58 years). Metrics were calculated according to the fifth edition of the American College of Radiology BI-RADS system and compared with concurrent DM examinations, previously published BCSC and National Mammography Database benchmarks, and expert-opinion acceptable performance ranges. Benchmarks were derived from the distribution of metrics across radiologists (84 or 73 depending on the metric) and are presented as percentiles.

Main results

With DBT, the abnormal interpretation rate was 8.3% (95% CI: 7.5-9.3); the cancer detection rate was 5.8 per 1000 screens (95% CI: 5.4-6.1); sensitivity was 87.4% (95% CI: 85.2-89.4); specificity was 92.2% (95% CI: 91.3-93.0); and the false-negative rate was 0.8 per 1000 screens (95% CI: 0.7-1.0). Compared with concurrent DM and prior benchmarks, all metrics were higher with DBT except sensitivity and the false-negative rate, which were similar. Acceptable performance ranges were reached by 97.6% of radiologists for cancer detection, 91.8% for sensitivity, 75.0% for abnormal interpretation rate and 74.0% for specificity.

What it means

The findings suggest that digital tomosynthesis detects more cancers without a disproportionate rise in additional examinations, and that most radiologists using it fall within acceptable performance ranges. Having percentiles for each metric helps centres see where they stand relative to reference practice and guides their quality improvement efforts.

A breast unit perspective

For a breast unit, these benchmarks are a useful self-assessment tool: they allow regular review of detection, recall and false-negative rates against international standards. Adopting tomosynthesis, where resources allow, is part of that continuous quality improvement in screening.

Reference: Breast Cancer Surveillance Consortium. National Performance Benchmarks for Screening Digital Breast Tomosynthesis: Update from the Breast Cancer Surveillance Consortium. Radiology, 2023. DOI

Leave a Reply

Your email address will not be published. Required fields are marked *