Home / Research / Automation bias shapes AI-assisted mammography reading

Automation bias shapes AI-assisted mammography reading

A prospective experiment with 27 radiologists shows that support from an artificial intelligence (AI) system can bias mammography reading: when the AI suggests an incorrect BI-RADS category, readers tend to accept it, and this tendency is strongest among the least experienced.

What was known

Automation bias is the human propensity to favour suggestions from automated decision-making systems, and it is a recognised source of error in human-machine interactions. Its specific impact on AI-aided mammography reading, however, had not been studied.

What this work adds

This was a prospective experiment in which 27 radiologists read 50 mammograms and gave their BI-RADS assessment with the aid of a purported AI system. The mammograms were obtained between January 2017 and December 2019 and were presented in two randomised sets. The first, a training set, contained 10 mammograms in which the system suggested the correct category. The second, of 40 mammograms, included 12 cases in which the AI suggested an incorrect category. Reader performance, the degree of bias in BI-RADS scoring, perceived accuracy of the system and each reader’s confidence in their own rating were assessed.

Main results

The percentage of correctly rated mammograms depended on whether the AI prediction was correct: for inexperienced readers it fell from 79.7% ± 11.7 to 19.8% ± 14.0; for moderately experienced readers, from 81.3% ± 10.1 to 24.8% ± 11.6; and for very experienced readers, from 82.3% ± 4.2 to 45.5% ± 9.1 (P = .003). Inexperienced readers were significantly more likely to follow the AI when it suggested a higher BI-RADS category than the actual ground truth, compared with both moderately experienced readers (mean degree of bias 4.0 ± 1.8 vs 2.4 ± 1.5; P = .044) and very experienced readers (4.0 ± 1.8 vs 1.2 ± 0.8; P = .009).

What it means

The authors conclude that radiologists at every level of experience are prone to automation bias when reading mammograms with AI support. This and other effects of human-machine interaction must be considered to ensure safe deployment and accurate diagnostic performance when combining human readers and automated systems. The study does not assess the clinical benefit of AI, but how it shapes the judgement of the professional using it.

A view from the breast unit

For a breast unit, the practical message is that introducing AI into screening requires more than buying the tool: reader training, protocols for verifying suggestions and regular audit of readings. Double reading and quality-control pathways remain relevant in this new setting.

Reference: Automation Bias in Mammography: The Impact of Artificial Intelligence BI-RADS Suggestions on Reader Performance. Radiology, 2023. DOI

Leave a Reply